電壓35kv
電流100A
質(zhì)保一年
認證CCC
材質(zhì)防觸電
ABB避雷器放電記錄儀--上海伽豪自動化隨時歡迎您的來電查詢,如需選型請及時來電,希望合作愉快!
Data can be downloaded and analyzed with special software through mobile computer and 485-232 transfer interface. Overall dimension, installation method and wiring diagram Overall dimension

Method of use1. Connect the corresponding wiring according to the operation manual; 2. When powered on, the LCD is displayed in turn according to the sequence of phase a counting, phase B counting and phase C counting; 3. Short touch the "F" key to check phase a count, phase B count, phase C count, local address, current date and current address in turn Time, when the current time is displayed, if it is djs-ii type, press the "F" key three times to zero the leakage current value (please pull out the data cable during zero calibration).

Long press the "F" key, then "CLR" will prompt whether all counts are cleared, and "-" will be displayed. After a "-" appears Execute the reset operation, and release the "F" key to exit before a "-" appears; 5. After pressing "▲" and "▼" at the same time to enter the setting state, the "year" bit flashes first, which can be adjusted by up and down keys; adopt Short touch "F" to switch to "month", "day", "hour", "minute" and "second" in sequence. When the second adjustment is over, short touch "F" to display the address code of the counter. If adjustment is needed, press "▲" and "▼" to adjust, and the adjustment will take effect immediately; During the adjustment, if the operation stops at any position for more than 7S, the standby state will be restored automatically, and the previous adjustment is effective. 6. Relevant data can be managed by background software through 485 bus;

Scope of application: 3 ~ 35kV system discrete lightning arrester without (with Series) gap; 2. Power supply: AC / DC 110 ~ 220V, < 1.5W;3. Counting form: A, B and C phases are counted separately and displayed on centralized LCD; 4. Minimum capture discharge current: < 10A; 5. Minimum capture pulse width: < 1 μ s; 6. Leakage current monitoring range: 0 ~ 20mA; 7. Built in clock, power failure holding time: half a year; 8. Storage capacity: > 2000 pieces; 9. Communication interface: 485, class Modbus protocol; 10. Independent address code can be set
適用范圍:3~35kV系統(tǒng)無(帶串聯(lián))間隙離散型避雷器;2.電源:交流/直流110~220V,<1.5W;3.計數(shù)形式:A、B、C相分別計數(shù),集中液晶顯示;4.小捕獲放電電流:<10A;5.小捕獲脈沖寬度:<1μs;6。泄漏電流監(jiān)測范圍:0~20mA;7.內(nèi)置時鐘,斷電保持時間:半年;8.存儲容量:>2000件;9通訊接口:485,Modbus類協(xié)議;10可以設(shè)置立的地址代碼
http://www.xinanyun56.com