電壓35kv
電流100A
質保一年
認證CCC
材質防觸電
產品特點:三相集中計數,放電時間條形記錄,通訊,電子液晶顯示。DJs系列高靈敏避雷器放電記錄儀的工作原理及產品組成主要由采樣器、傳感器、轉接盒、顯示器、配套傳輸電纜及部分電子元器件組成。在正常工作電壓下,通過避雷器的泄漏電流變化通過采樣器及相關電纜傳輸至顯示器,并通過顯示器中的放大電路和a/D轉換電路轉換為數字信號,在顯示器中的微處理器控制下顯示。當避雷器流過雷擊波、工作波或工頻過電壓時,強動作電流從泄漏電流測量電路傳輸到反電路,泄漏電流測量電路受到保護。計數器部分利用電磁感應原理獲取工作波或工頻過電壓電流信號,然后在顯示器上經微處理器處理,記錄動作次數
Data can be downloaded and analyzed with special software through mobile computer and 485-232 transfer interface. Overall dimension, installation method and wiring diagram Overall dimension

Long press the "F" key, then "CLR" will prompt whether all counts are cleared, and "-" will be displayed. After a "-" appears Execute the reset operation, and release the "F" key to exit before a "-" appears; 5. After pressing "▲" and "▼" at the same time to enter the setting state, the "year" bit flashes first, which can be adjusted by up and down keys; adopt Short touch "F" to switch to "month", "day", "hour", "minute" and "second" in sequence. When the second adjustment is over, short touch "F" to display the address code of the counter. If adjustment is needed, press "▲" and "▼" to adjust, and the adjustment will take effect immediately; During the adjustment, if the operation stops at any position for more than 7S, the standby state will be restored automatically, and the previous adjustment is effective. 6. Relevant data can be managed by background software through 485 bus;

Scope of application: 3 ~ 35kV system discrete lightning arrester without (with Series) gap; 2. Power supply: AC / DC 110 ~ 220V, < 1.5W;3. Counting form: A, B and C phases are counted separately and displayed on centralized LCD; 4. Minimum capture discharge current: < 10A; 5. Minimum capture pulse width: < 1 μ s; 6. Leakage current monitoring range: 0 ~ 20mA; 7. Built in clock, power failure holding time: half a year; 8. Storage capacity: > 2000 pieces; 9. Communication interface: 485, class Modbus protocol; 10. Independent address code can be set

Method of use1. Connect the corresponding wiring according to the operation manual; 2. When powered on, the LCD is displayed in turn according to the sequence of phase a counting, phase B counting and phase C counting; 3. Short touch the "F" key to check phase a count, phase B count, phase C count, local address, current date and current address in turn Time, when the current time is displayed, if it is djs-ii type, press the "F" key three times to zero the leakage current value (please pull out the data cable during zero calibration).
使用方法 按照操作手冊連接相應的接線;2.通電時,LCD按a相計數、B相計數、C相計數順序依次顯示;短“F”鍵,依次檢查a相計數、B相計數、C相計數、本地地址、當前日期和當前地 時間,當顯示當前時間時,如果是djs ii型,按“F”鍵三次,將泄漏電流值歸零(歸零校準時請拔出數據電纜)。
http://www.xinanyun56.com