電壓35kv
電流100A
質(zhì)保一年
認(rèn)證CCC
材質(zhì)防觸電
DJs百度系列高靈敏避雷器放電記錄儀功能簡介DJs系列高靈敏避雷器放電記錄儀(以下簡稱DJs)是一種用于室內(nèi)使用的電子式避雷器放電計(jì)數(shù)器(可選避雷器泄漏電流在線監(jiān)測)。適用于35KV以下無(串聯(lián))間隙避雷器的放電計(jì)數(shù)??捎涗洷芾灼鱝、B、C放電動(dòng)作次數(shù)及相應(yīng)放電時(shí)間,液晶顯示,數(shù)據(jù)記錄量1000次以上,抗干擾能力強(qiáng),靈敏度高,并提供網(wǎng)絡(luò)通信和數(shù)據(jù)下載接口。
Method of use1. Connect the corresponding wiring according to the operation manual; 2. When powered on, the LCD is displayed in turn according to the sequence of phase a counting, phase B counting and phase C counting; 3. Short touch the "F" key to check phase a count, phase B count, phase C count, local address, current date and current address in turn Time, when the current time is displayed, if it is djs-ii type, press the "F" key three times to zero the leakage current value (please pull out the data cable during zero calibration).

Scope of application: 3 ~ 35kV system discrete lightning arrester without (with Series) gap; 2. Power supply: AC / DC 110 ~ 220V, < 1.5W;3. Counting form: A, B and C phases are counted separately and displayed on centralized LCD; 4. Minimum capture discharge current: < 10A; 5. Minimum capture pulse width: < 1 μ s; 6. Leakage current monitoring range: 0 ~ 20mA; 7. Built in clock, power failure holding time: half a year; 8. Storage capacity: > 2000 pieces; 9. Communication interface: 485, class Modbus protocol; 10. Independent address code can be set

Data can be downloaded and analyzed with special software through mobile computer and 485-232 transfer interface. Overall dimension, installation method and wiring diagram Overall dimension

Long press the "F" key, then "CLR" will prompt whether all counts are cleared, and "-" will be displayed. After a "-" appears Execute the reset operation, and release the "F" key to exit before a "-" appears; 5. After pressing "▲" and "▼" at the same time to enter the setting state, the "year" bit flashes first, which can be adjusted by up and down keys; adopt Short touch "F" to switch to "month", "day", "hour", "minute" and "second" in sequence. When the second adjustment is over, short touch "F" to display the address code of the counter. If adjustment is needed, press "▲" and "▼" to adjust, and the adjustment will take effect immediately; During the adjustment, if the operation stops at any position for more than 7S, the standby state will be restored automatically, and the previous adjustment is effective. 6. Relevant data can be managed by background software through 485 bus;
使用方法 按照操作手冊(cè)連接相應(yīng)的接線;2.通電時(shí),LCD按a相計(jì)數(shù)、B相計(jì)數(shù)、C相計(jì)數(shù)順序依次顯示;短“F”鍵,依次檢查a相計(jì)數(shù)、B相計(jì)數(shù)、C相計(jì)數(shù)、本地地址、當(dāng)前日期和當(dāng)前地 時(shí)間,當(dāng)顯示當(dāng)前時(shí)間時(shí),如果是djs ii型,按“F”鍵三次,將泄漏電流值歸零(歸零校準(zhǔn)時(shí)請(qǐng)拔出數(shù)據(jù)電纜)。
http://www.xinanyun56.com